Phone: 8333923733 | eMail: tsfiresupport@cgg.gov.in


Skip Navigation LinksHome > Services > tsipass
Telangana State Disaster Response Fire & Services Department - TS-IPASS Guidelines
1.The Operational Guidelines of TS-iPASS Act-2014

(i) Industries Below 15 Mtrs height (Low & Medium Hazard) concerned District Fire Officer.
(ii) Industries Below 15 Mtrs height (High Hazard) Regional Fire Officer, Central Region, B.R.K.Rao Building, 1st Floor, ‘B’ Block,
Hyderabad.
(iii) Industries above 15 Mtrs height (High Hazard)Director General of State Disaster Response and Fire Services, Telangana,
B.R.K.Rao Building, 1st Floor, ‘B’ Block, Hyderabad
2.TS-iPASS Common Application Form

2(i) The additional requirements in Common Application Form is enclosed at Annexure to TS iPASS Common Application Form
3. Required Enclosures

A.Before/prior to construction activity (forms, enclosures, certificates, self-declarations, approval rules, fee structure, etc.) for the issuance of provisional noc. Appropriate self appraisal/check list viz., chemical industries, pharmaceutical industries, rubber industries etc., available at fireservices.Ap.Gov.In
Plans duly marking fire fighting systems in red complying with requirements as per rule 15 of a.P.Fire and emergency operations and levy of fee rules 2006.
In addition to the above the following docucments shall be enclosed in respect of the buildings which are more than 15 mtrs heights & large scale industries for obtaining provisional no objection certificate
Estimation towards the provision of required fire safety systems.
15% bank guarantee on the estimated cost of the fire safety system.
Under taking on rs.100/- stamp paper in form no.17 of a.P.Fire and emergency operations and levy of fee rules 2006.
Risk analysis report on the proposed industry obtained from a third party technical expert/agency duly mentioning the various fire /explosion risk involved in the process and safety measures required in respect of medium and large scale industries.
Check list in form no.16 of a.P.Fire and emergency operations and levy of fee rules 2006.
B.For commercial production (forms, enclosures, certificates, approval rules, fee structure, etc.) for issuance of noc for occcupancy
As built plans duly marking fire fighting systems complying with requirements as per rule 15 of a.P.Fire and emergency operations and levy of fee rules 2006 & as per the conditions of provisional no objection certificate.
The contact details of technical person for any technical clarifications.
Third party safety audit report on the industry obtained from a third party technical expert/agency duly mentioning the various fire safety measures provided in respect of large scale industries, and industries above 15 meters height.
Additional requirements for industrial buildings above 15 mtrs height.
Form no.16 & form no.19 of a.P.Fire and emergency operations and levy of fee rules 2006..
Provide updated information in the above form which shall truly reflect the as installed and as built status of site and shall signed by authority technical person.
Make (4) copies of provisional noc drawings clearly showing the as built and corrections if any. These must be certified by competent architect and engineer.
Certified electrical drawings, specifications of fire safety related equipment with details of technical person for any technical clarifications.
C.Fire Precaution Fee
(i) Before/prior to construction activity for the issuance of provisional noc.
Below 15 mtrs height building and all small scale industries which are covered by factories act,1948 for rs.500/- (through challan) .
Below 15 mtrs height building and medium scale industries /factories registered under factories act,1948 for rs.5000/- (through challan).
Above 15 mtrs height buildings rs.10/- per sq. Mtrs. On total built up area (including parking cellars) (through challan) .
Challan head of account:
0070-other administrative services.
060-other services.
109-fire protection and control.
081- other receipts .
(ii) For commercial production for issuance of noc for occcupancy.
10% of statutory fee subject to maximum 50,000/- for under taking inspection for issuance of noc for occupancy.
If not obtained provisional no objection certificate and applied for noc for occupancy rs.10/- per sq. Mtrs. On total built up area (including parking cellars) (through challan). In addition,the penal interest in respect of fire protection fees be levied at the rate of 24% per annum from the date of construction and till such time noc is obtained from the fire service department as per g.O. Ms.No. 154 municipal administration & urban development department (m1) department dt, 13-3-2007.
Remit the user charges of 10% of statutory fee subject to maximum 50,000/- for under taking inspection for issuance of occupancy certificate for second and subsequent inspections as per g.O.Ms.No. 71 home (prisons.A) department dt, 1-4-2010.
4. Hardware availability in the Office.

a) Computers and Printers available
b) Requires Server with LAN connection for client server communication
5.Net Connectivity.

Net connection is required to be provided
6.Competent authorities to receive the Applications.
State Level
Sl.noDesignationEmail
1 Director General of Telangana State Disaster Response and Fire Services, B.R.K.Rao Building, 1st Floor, ‘B’ Block, Hyderabad. ts_firechief@yahoo.com

Regional Level
Sl.noDesignationEmail
1 Regional Fire Officer, Central Region, B.R.K.Rao Building, 1st Floor, ‘B’ Block, Hyderabad rfo_cr@yahoo.com

District Level
Sl.noDesignationMobileNoEmail
1 District Fire Officer, Mahaboobnagar 9949991077 dfo_mbnr99@yahoo.com
2 District Fire Officer, Nalgonda 9949991080 dfo_nalgonda@yahoo.com
3 District Fire Officer, Nizamabad 9949991082 dfo_nzb@yahoo.com
4 District Fire Officer, Warangal 9949991084 dfo_wrl@yahoo.com
5 District Fire Officer, Adilabad 9949991090 dfo_adilabad@yahoo.com
6 District Fire Officer, Khammam 9949991088 dfo_khammam@yahoo.com
7 District Fire Officer, Karimnagar 9949991086 dfo_krm@yahoo.com
8 District Fire Officer, Medak 9949991078 dfo_mdk@yahoo.com
9 District Fire Officer, West Zone, Madhapur, Ranga Reddy 9949991092 dfo_rrd@yahoo.com
10 District Fire Officer, South Zone, Gowliguda, Hyderabad 9949991094 dfo_hyd@yahoo.com
11 District Fire Officer,North Zone, Secunderabad 8008559143 dfo_northzone@yahoo.com
12 District Fire Officer, East Zone, Ibrahimpatnam, Ranga Reddy District 8008559142 dfo_eastzone@yahoo.com
13 District Fire Officer, Central Zone, Legislative assembly, Hyderabad. 8008559147 dfo_centralzone@yahoo.com
14 District Fire Officer, Telangana State Fire Services & Civil Defence Training Institute, Vattinagulapalli, Ranga Reddy District 9704300644 dfo_fscdti@yahoo.com
7.Name and contact details of the single point nodal officer of the department for informing the status of the application.
Additional director telangana state disaster response and fire services, b.R.K.Rao building, 1st floor, ‘b’ block, hyderabad. Mobile no. 9849906105
8.Officers authorized to attend Pre-Scrutiny meetings.
Industries below 15 mtrs height concerned district fire officer and asst. District fire officer .
Industries above 15 mtrs height regional fire officer, central region, Hyderabad and concerned district fire officer. 9. Ts-ipass applications inspection procedure

Sl.No.

Description

Inspecting Authority

1

Industries Below 15 Mtrs height

Asst. District Fire Officer and Jurisdictional Station Fire Officer

2

Industries above 15 Mtrs height

(High Hazard)

District Fire Officer and

Jurisdictional Station Fire Officer


ANNEXURE to TS iPASS Common Application Form